Daniel® SeniorSonicTM Gas Flow Meter with Mark III Electronics

 

The Daniel® SeniorSonic™ Gas Ultrasonic Flow Meter is designed for custody transfer and other applications requiring high accuracy.  The SeniorSonic Meter has outstanding low-to-high accuracy of ± 0.1 % with greater than 100:1 rangeability after flow calibration and excellent long-term measurement performance.

Mark III™ Electronics, a completely re-engineered electronics platform, is now available with the SeniorSonic Flow Meter.  With Mark III Electronics, the Daniel SeniorSonic meter processes data much faster and is easier to use.  Customers can add functionality by replacing the electronics.  Added functionality for the Mark III Electronics is now available in the form of the Series 100 Plus board.  This new option board allows the meter to communicate directly with a digital plant architecture via the HART protocol, such as PlantWeb® AMS Suite, or a 375 Field Communicator. It also permits the meter to provide integral flow computer capabilities, including the ability to calculate real time corrected volume, energy, mass flow rate, and AGA10 speed of sound.  This data is stored in the extensive non-volatile audit logs.

Daniel Ultrasonic meters are further complimented with innovative and easy to use Daniel CUI 4.21 Software.  A recent upgrade to the successful Daniel CUI Software includes many new features that Daniel customers have requested.

 

Innovative Options for
Gas Ultrasonic Flow Meters

Request Information

 

Key features/benefits

  • Four-path chordal design allows accuracy, stability, redundancy, and operational cost savings
  • Excellent long-term performance reduces
    maintenance costs
  • High rangeability of >100:1 means fewer meter runs, smaller line sizes, and lower capital costs
  • CUI (Customer Ultrasonic Interface) Software offers easy-to-use and learn Windows® based meter interface software, reduces time to commission a new meter, and simplifies routine maintenance
  • Mark III Electronics provides faster sampling and output, expandable electronics platform, ease of use, and an optional archive data log* which enables the reading of audit, alarm, system, hourly, and daily
    log information

 

 

 

  • Optional Series 100 Plus Board provides a direct input of pressure, temperature, and gas composition into the meter which allows the meter to act as a redundant flow computer; it calculates corrected volume rates, mass rates, energy rates, and AGA10 speed of sound*.
  • Machined, cast body construction is virtually insensitive to measurement uncertainty caused by changes in pressure

  • Extractable transducers for ease of inspection

 

Key industries/applications

  • Custody Transfer
     

  • Power plants

  • Large Industrial users

  • City gates

  • Production

  • Underground storage cites

  • Offshore

 

 

 

Daniel CUI 4.21 Standard Manual 1.4MB.pdf

 

Daniel CUI 4.21 Deluxe Manual 1.4MB.pdf

 

 

Download Daniel CUI 4.21 Standard 8MB.zip

 

Download Deluxe Upgrade Daniel CUI 4.21 8MB.zip

 

 

 

Firmware Installation Instructions 29KB.pdf

 

 

Gas USM Firmware 1.61 3MB.zip

 

 

GUSM PlantWeb Flyer 1.1MB

Ultrasonic Meter Family Brochure 1.7MB

CUI 4.10 Announcement
KKrebs 83KB pdf

Mark III ATEX Cert 200KB.pdf

SeniorSonic and JuniorSonic Ultrasonic Meter Datasheet 2.3MB.pdf

Mark III UL-CSA Approval Cert 183KB.pdf

Product Bulletin August 10, 2004

Hoist Ring Bulletin 83KB.pdf

Hoist Ring Safety Notice 109KB.pdf

GUSM Mark II Parts 34KB.pdf

GUSM Mark II Inactive 24KB.pdf

GUSM Mark III FAQ's 53KB.pdf

GUSM Low Pressure 30KB.pdf

GUSM Connection 39KB.pdf

Click here for more
Catalogs/Spec sheets

 

Ultrasonic Meter T-2 to T-11 Tranducer Upgrade Instructions 3.2MB.pdf

 

Series 100 Option Board Installation Manual 1.5MB.pdf

 

Mark III Modbus Table 386KB.xls

 

Ultrasonic Mark III Electronic Upgrade Kit Instruction 6MB.pdf

 

PED Specific Installation and Operation of Ultrasonic Meters All 89KB.pdf

 

Ultrasonic Mark III Ref Install and Ops Manual All 8.6MB pdf 

 

Mark II Ref Install and Ops Manual 5MB pdf

Click here for more
Product Manuals/Drawings

 

Daniel CUI 4.21 Standard Manual 1.3MB.pdf

 

Daniel CUI 4.21 Deluxe Manual 1.5MB.pdf

HART Field Device Specification Guide
1 MB.pdf

 

 

NSFMW 2005, How Today's USM Diagnostics Solve Metering Problems 352KB.pdf

 

WGMSC 2005, How Todays Advanced USM Diagnostics Solves Metering Problems
235KB pdf

 

NSFMW 2004 - Dirty vs. Clean Ultrasonic Gas Flow Meter Performance
700KB pdf

 

NSFMW 2004 - A Powerful New Diagnostic Tool for Transit Time Ultrasonic Meters
KZanker 210KB pdf

 

ASGMT 2004 - Overview of AGA 9 185KB.pdf

 

AGA 2004 - Design Considerations for USMs 269kb.pdf

 

Ultrasonic Solution for High Pressure Gas Service by Mike Hopkins 143KB.pdf

 

Performance Test of Daniel 12inch Profiler Plate Flow Conditioner 201KB.pdf

 

Pipeline and Gas Technology reprint - Contamination Affects Accuracy 600KB.pdf

 

AFMS 2003, Ultrasonic Gas Meter Station Design, CDerr 743KB.pdf

 

WGMSC 2003, Ultrasonic Meter Station Design Considerations 330KB.pdf

 

WEI 2003, Basics of USMs 109KB.pdf

 

SEA 2003, Diagnostics of the Daniel USM, KZanker 163KB.pdf

 

AGA 2003, How to Simplify and Automate Maintenance of Today's USM 769KB.pdf

 

 

Click here for more
Application Notes/Papers

 
 

 

Send comments to:
webmaster@daniel.com

 


 

 


© Emerson, 1996-2008
Legal and Privacy Statements